One panel
Scrap or rework it. The cost is the panel.
Prototype Manufacturing · PUF sandwich panels
A hidden foam void looks perfect from outside. It shows up weeks later, when the panel bows on site or ices over in a cold room. Here a thermal camera finds it while the panel is still warm, a second camera checks the skin, and every panel leaves the plant with a record the buyer can scan, back to the chemical drums and steel coils it was made from.
A PUF panel is two steel skins with foam poured between them. If the mix runs a little cold or the ratio drifts, the foam leaves an air pocket or doesn't stick to the skin. From outside the panel looks fine. Today's checks, a tap test and a tape on a few panels per batch, mostly miss it.
Where a defect gets caught
Mix drifts: flagged before bad panels pile up
Tape check, 1 panel in 20
Void seen as a cold patch, every panel
A glance, if someone's free
Dents and scratches, every panel
Panel leaves with its record
Panel bows, joints don't close
Sweating, ice patches, power bills
Scrap or rework it. The cost is the panel.
A new panel, freight both ways, a crew to pull and re-fit it, and a contractor who now checks every load.
Ice, sweating walls and higher power bills before anyone traces it back. Pharma and food clients ask for proof, and there isn't any.
Foam gives off heat as it sets, so a fresh panel is warm all over. An air pocket doesn't make heat, so it shows up as a cold patch. Flip the view to see the same panels the way the thermal camera does.
Line 1 · event log2:02 pm
A simulation of the prototype's output, not footage from a plant. Panel sizes, temperatures and messages follow a real 80 mm wall-panel line.
A panel's foam comes from a drum of polyol, a drum of isocyanate and a blowing agent. Its skins come from two steel coils. Every lot is lab-tested before it's allowed near the line, every run is tested after, and every panel carries the whole family tree.
Sample lots, results and sites. Specs are typical for 40 kg/m³ PUF wall panels; each plant sets its own.
Gate 1 · every lot that comes in
Gate 2 · samples from every run
The same hidden fault costs different things in different rooms. Pick one.
What goes wrong
What the panel record proves
Every wall panel's chemical lots, lab results, thermal scan and size check, filed with the room's qualification papers.
Result for the plant
Rooms that hold pressure and pass particle tests first time, and an audit question answered in minutes.
What goes wrong
What the panel record proves
Which panel is which on the wall, and which lots and mix made it, so a warm patch is traced to its cause, not argued over.
Result for the farmer
An even 3 °C wall to wall, lower power bills, and repairs on the two panels at fault, not the whole store.
What goes wrong
What the panel record proves
Which panels sit over the product zones and what they were made from, so the plant replaces the right ones before they drip.
Result for the plant
Dry ceilings, clean audits, and a wall that still insulates in year ten the way it did in year one.
Simulations, not footage. The ten-year curves are illustrative: a pilot measures panels at the plant, and site data would come from buyers who share it.
More rooms that depend on the panel
Each output goes to the one person who acts on it, where they already are.
Line 1 · QC
Panel 1,284 held. Cold patch about 40 × 25 cm, 30 cm from the joint edge.
2nd cold patch in 6 panels. Isocyanate at 19 °C, set point 22 °C, since 2:09 pm.
→ Check the iso heater.
→ Tap-test panels 1,280 to 1,285.
Thermal image and both faces attached
Shift B report13 Nov · 2 pm to 10 pm
What caused the holds
Sample outputs from the prototype, with made-up panel numbers.
Hears about a bad batch when a contractor calls, angry.
Sees every hold the same day, with the cause behind it.
Site complaints per month
Tap-tests a few panels per batch and hopes they're typical.
Every panel checked; tap tests go only to the ones flagged.
Panels checked per shift
Finds out the mix ran cold after twenty bad panels.
Told within two panels, with what to check first.
Bad panels per drift
"It was fine when it left" is all they can say.
Pull up that exact panel's thermal image and photos.
Disputes settled with proof
Checks each load by eye, and still gets surprises.
Scans the label. Knows what was checked and when.
Panels sent back from site
Asks for quality records. Gets a test certificate per order.
Gets a record per panel for their audit file.
Orders where proof wins the bid
Every number here is an assumption, filled with typical values. Change any of them. The sum is shown in full under the result, so you can check it.
Right after the saw, while the foam is still warm. A cold patch means foam that didn't fill or didn't stick.
Looks at both faces for dents, scratches and coating damage, before the protective film hides them.
Laser sensors measure length, thickness and squareness on every panel, not one in twenty.
Reads temperatures, pressures and the mix ratio. When faults line up with a drift, it names the drift.
The pilot runs beside your current QC, not instead of it. Every hold gets a tap test or a cut sample, so the numbers are checked, not claimed.
Sit on the line. Log faults the way your team finds them today. That's the baseline.
Fit the cameras and sensors in a planned stop. Record every panel without flagging anything.
Train on your panels. Tune it until false alarms are rare enough to trust.
Run live, side by side with your QC. Count what each one caught.
Results: published on this page when the first pilot ends, whatever they are.
The cameras and models change; the idea doesn't. See every unit, find faults where they start, and send a record with the product.
Not directly. It sees heat. Setting foam is warm, and a void or a skin that hasn't bonded stays cooler, so it shows as a cold patch for a few minutes after the press. That's why the camera sits right after the saw. Very small or very deep voids can still be missed, which is why the pilot measures what it catches against tap tests.
Usually not. The cameras and sensors mount over the line, and the machine data is read, never written. If the dosing machine has no data port, we start with the cameras alone.
A false alarm costs a tap test, and the supervisor's "False alarm" reply teaches it. A missed fault is what the pilot is there to count. Nothing is scrapped automatically; a person decides.
No. It runs on a computer beside the line. Messages and panel records go out when there's a connection.
You do. Images stay on your plant computer. We only use them to train your models.
Send us a month of rejects and complaints. We'll put your numbers in the model above and tell you honestly if a pilot is worth it.